PACKING GLAND ADJUSTMENT 


 CLAMPSEAL® Throttling valves have a precision packing system with a single piece splined gland. Packing should be adjusted periodically to prevent leakage. See Table 3 for gland torques. Adjustment is especially important after hydro test or startup.

 Most CLAMPSEAL® valves are furnished with an Integral Gland Wrench, Figure A. The I.G.W. provides for easy packing maintenance which helps extend packing life. Cycle valve several times while adjusting packing to improve packing seal.

FIGURE A

         
  GLAND WRENCH  
  FOR VALVES NOT FITTED WITH  
  INTEGRAL GLAND WRENCH  
  INTEGRAL GLAND WRENCH  
  CURRENTLY SUPPLIED ON  
  STANDARD VALVES  