SUPPLEMENTARY INSTRUCTIONS
A. Factory Mounted Motor Operators
Factory mounted operators should not be removed from the valve prior to installation. The torque switches which have been set prior to hydro testing and should not require field adjustment.
B. Mounting of CLAMPSEAL® valve to Motor Operator in Field
This procedure applies where a valve is being mated with an existing operator:
DO NOT USE THE OPEN TORQUE SWITCH TO DE-ENERGIZE THE VALVE!
C. STORAGE
All valves are treated with rust-preventative, capped, and sealed in polyethylene bags to repel moisture. Valves should be stored in a weatherproof enclosure on pallets or shelving to isolate valve from moisture.
D. HANDLING
CLAMPSEAL® valves are extremely rugged and damaging them during handling is difficult. However, some care must be taken in handling. Do not drop them. Use yoke arm or body to lift valve. Do not lift by valve handle.
E. TORQUE TOOLS
The following torque tools are available:
TORQUE YOKE WRENCH Optional
Torque Handle for YOKE WRENCH
![]()
TORQUE GLAND WRENCH